C&I ESS series

Our Commercial ESS Solution is designed for commercial and industrial use, with a modular integrated architecture combining batteries, BMS, PCS, and an intelligent EMS. It supports grid-tied, off-grid, and microgrid operations, offering peak shaving, load shifting, backup power, and renewable energy integration to cut electricity costs and improve supply reliability. Featuring high safety, long lifespan, and scalability, it is ideal for parks, supermarkets, data centers, etc., helping enterprises achieve cost-effectiveness, efficiency improvement, and green transition.

 

Commercial & Industrial Energy Storage Parameters
Battery System Parameters ESS-100kWh/112kWh ESS-57kWh/64kWh
Battery Module Type 51.2V 280/314Ah 51.2V 280/314Ah
Battery Module Number 7 4
Battery Module Dimension 442*750*230mm 442*750*230mm
Battery System Voltage 358.4V 358.4V
Battery Capacity 280 /314Ah 280 /314Ah
Normal Energy 100 /112KWh 57/64kWh
Battery Max Charge Current 140A /157A 140A/157A
Battery Max Discharge Current 140A /157A 140A/157A
Charge Voltage 386.4V 220.8V
Cut-off Voltage 313.6V 179.2V
50/20kW Inverter Parameters
Battery Parameters
Max Battery Voltage
850V 850V
Min Battery Voltage 200V 180V
Normal Voltage Range 320V~850V 180V~850V
Max Charge/Discharge Current 150 100
PV Parameter
Max Power
38.4KW+38.4KW 19.2KW+19.2KW
Max PV Voltage 850V 850V
PV Start Voltage 250V 250V
MPPT Voltage Range 200V~800V 200V~800V
Max PV Current 64A+64A 32A+32A
On Grid
Normal Power
50KVA 18KVA
Normal Current 73A 26A
AC voltage 400V/230V 400V/230V
AC voltage range -20%~15% -20%~15%
Frequency Range (50Hz/47Hz~52Hz)
(60Hz/57Hz~62Hz)
(50Hz/47Hz~52Hz)
(60Hz/57Hz~62Hz)
Power Factor -0.8~0.8 -0.8~0.8
Off Grid
Normal Power
50KVA 18KVA
Max Out Power 55KVA 21KVA
Normal Current 73A 26A
Max Output Current 80A 30A
AC Voltage 400V/230V 400V/230V
Output Voltage Harmonics <3%resistive load) <3%(resistive load)
Degree Of Unbalance 1 1
Frequency Range 50/60HZ 50/60HZ
Overload (39.8A<l load≤45A/100s
45A<I load≤54A/100ms)*2
(28.6A<l load≤32.5A/100s
32.5A<l load≤39A/100ms)
Cabinet
Cooling Air conditioner Air conditioner
System Weight 1200kg 900kg
Dimension Approx 1000*1450*2100mm Approx 800*1450*2000mm
Inverter Installation Built-in Cabinet Built-in Cabinet
Indoor High-Voltage Industrial & Commercial Energy Storage Cabinets Parameters
Battery type-Chemistry LiFePO4
Module Nominal Voltage 51.2V
Module Capacity 100/200/314Ah
Normal Energy 5.12/10.24/16.08kWh
Battery Module Qity in Series 4 6 8 10 12 14
System Nominal Voltage 204.8V 307.2V 409.6V 512V 614.4V 716.8V
Charge Voltage 220.8~230.4V 331.2~345.6V 441.6~460.8V 552.0~576.0V 662.4~691.2V 772.8~806.4V
Cut-Off Discharge Voltage 172.9V 268.8V 358.4V 448.0V 537.6V 627.2V
Max.Charge Current 100/200/157A
Recommended Charge Current 20/40/60A
Max.Discharge Current 100/200/157A
Recommended Discharge Current 20/40/60A
Discharge Temperature -20℃~60℃
Charging Temperature 0℃~55℃
Storage Temperature -10℃~45℃
Communication Port CAN/RS485
IP Rating of Enclosure IP20
Installation Location 5
Max.in Parallel Indoor
LCD Screen Optional
Cooling FAN(Optional)
Cycle life(0.2C,25℃@80%DOD) ≥6000 Cycles
Design Life(25℃) 15 years
Certifications CE/IEC/RoHS/UN38.3
Outdoor DC-side Commercial And Industrial Energy Storage Cabinets Parameters
Battery System Parameters 50KWh 100kWh/112KWh 100kWh/122KWh 215KWh/241kWh
Model 512V100Ah 358.4V280/314Ah 512V206Ah/614.4V206Ah 768V280/314Ah
Assembly 10S1P 7S1P 10S1P 15S1P
Rated Voltage 512V 358.4V 512V/614.4V 768V
Rated Capacity 100Ah 280/314Ah 206Ah 280/314Ah
Standard Charging Voltage Range 552V~560V 386.4V~392V 552V~560V 828V~840V
Cut-off Voltage 448V 313.6V 448V 672V
Max.Continuous Discharge Current 100A 140/157A 200A 140/157A
Max.Charge Current 100A 140/157A 200A 140/157A
Operating temperature Ambient:-20℃~45℃ Charging:0℃~55℃ Discharge:-20℃~55℃
Storage Temperature -10℃~45℃
Transportation Temperature -20℃~55℃
Operating Humidity 5%~95%
Storage Humidity 5%~95%
Transportation Humidity 5%~95%
Protection Class IP54

Features
• High Safety & Reliability – LiFePO4, multi-layer protection, active fire suppression.
• High Efficiency & Long Lifespan – Efficient charging/discharging, long cycle life, low LCOS.
• Intelligent Monitoring & Management – Remote real-time monitoring, smart operation, unmanned maintenance.
• Flexible Scalability – Modular design, flexible power/capacity expansion.
• Easy Installation & Maintenance – Integrated, standard rack, simple & efficient.